Wiegand 26 Bit Explained: Format, Wiring, Limits and OSDP

Quick Summary

Key points

  • Wiegand 26 bit is a data format, not a type of card. It describes how 26 bits of information are arranged when a reader sends a credential number to the controller.
  • The 26 bits break into a facility code, a card number and two parity bits. That structure is what makes it both simple and limited.
  • The Wiegand interface itself is two data lines plus power and ground, and it only talks one way, from the reader to the controller.
  • The card number space is small enough that duplicate numbers across different sites are a genuine possibility, which is the main practical argument for moving beyond it.
  • OSDP is the modern replacement. It is two wire, it talks both ways, it can be supervised, and it supports encryption, none of which Wiegand does.
How the 26 bits are divided
PositionBitsWhat it carries
First bit1Even parity, covering the first half
Next8Facility code, giving 256 possible values
Next16Card number, giving 65,536 possible values
Last bit1Odd parity, covering the second half

Wiegand 26 bit turns up in two very different conversations. One is a specifier asking whether a reader will talk to an existing panel. The other is somebody troubleshooting a door where the reader beeps, the light changes, and nothing happens at the controller.

Both come back to the same thing: what the format is, how the wiring carries it, and where it runs out of room. This guide covers all three.

What Does Wiegand 26 Bit Actually Mean?

It means the reader sends the controller a number made of exactly 26 binary digits, arranged in a defined order that both ends agree on in advance.

The name causes confusion because Wiegand originally described a card technology built around a physical effect in specially treated wire. Those cards are long gone from most buildings. What survived is the wiring interface and the data format, and that is what people mean today.

So a modern proximity or smart card reader is almost never a Wiegand card reader. It is a reader of some other technology that outputs its result in Wiegand format.

Schlage MT multi technology reader module that outputs Wiegand 26 bit
A multi technology reader module. The card technologies it accepts and the format it sends to the controller are two separate specifications, and mixing them up is the most common source of confusion on these systems.

How Is a 26 Bit Wiegand Number Structured?

One parity bit, eight bits of facility code, sixteen bits of card number, one parity bit. That order, every time.

The facility code identifies the site or the card batch. The card number identifies the individual credential within that facility code. The two parity bits are a simple error check: the first covers the leading half of the message and the second covers the trailing half.

Why does a card show two numbers on it?

Because printed credentials often show the facility code and the card number separately, and the controller needs both. Enrolling a card using only the number printed largest on the front is a classic cause of a card that reads but is never recognised.

How Does the Wiegand Interface Send Data?

With pulses on two separate lines. One line carries the zeros, the other carries the ones, and the controller assembles the bits in the order they arrive.

Both lines sit high when nothing is happening. To send a zero the reader briefly pulls the first line low. To send a one it briefly pulls the second line low. Twenty six pulses later, across the two lines, the number is complete.

The important consequence is that the conversation only goes one way. The reader talks, the controller listens, and the controller has no way to ask the reader anything or to confirm it is still there.

What does one way communication cost you?

Supervision. If a Wiegand reader is disconnected, smashed or quietly swapped for another one, the controller does not know. It simply stops receiving data, which looks identical to nobody presenting a card.

Which Wires Does a Wiegand Reader Use?

Four as a minimum: two data lines, a positive supply and a common ground. Most installations add a shield or drain, and many readers have extra conductors for the beeper and the indicator so the controller can give the user feedback.

The usual Wiegand conductor convention
FunctionTypical colourNotes
Data zeroGreenPulses low to send a binary zero
Data oneWhitePulses low to send a binary one
Supply positiveRedVoltage range set by the reader specification
Common groundBlackMust be common with the controller
Shield or drainBare or foilEarthed at one end only

Treat colours as a convention rather than a guarantee, and confirm against the documentation for the specific reader. The ground is the one people get wrong: the reader and the controller have to share a common ground or the data lines have no reference and the reads become intermittent.

How far can a Wiegand reader be from the controller?

The figure usually quoted is around 500 feet, and it is a guideline rather than a hard edge. Cable type, conductor size, the supply voltage and electrical noise along the route all move it. If a reader is right at the limit and behaving unpredictably, distance is a reasonable first suspicion.

What Are the Limits of 26 Bit Wiegand?

Three, and they build on each other.

The number space is small. Sixteen bits of card number is 65,536 values, and eight bits of facility code is 256. A large organisation can exhaust that, and more importantly two unrelated sites can end up holding cards with identical facility code and number.

There is no security in the format. The number travels in the clear along two wires, and anything that can read those wires can capture it and replay it.

And there is no supervision, as above. The controller cannot tell a working reader from a missing one.

What the limits mean in practice
LimitPractical consequenceWhen it matters
65,536 card numbersDuplicates across sites are possibleLarge estates, shared landlord systems
256 facility codesCodes get reused between organisationsMulti tenant buildings
No encryptionThe number can be captured from the cableReaders on the unsecured side of a door
No supervisionA removed reader looks like an idle oneAny high security opening
One way onlyNo reader status, no remote configurationLarge systems with many doors

Why Do Facility Codes Matter So Much?

Because they are the only thing separating your card population from somebody else's, and there are only 256 of them.

On a single site with one facility code, the system is effectively checking a 16 bit number. If a neighbouring organisation happens to hold the same facility code, a card from their building carries a number your controller may recognise as valid.

That is why larger formats exist. More bits means a bigger number space and a much lower chance of collision, at the cost of needing both ends to agree on the longer format.

Can you mix formats on one system?

Sometimes, if the controller supports multiple formats simultaneously, but it is worth avoiding where you can. A site running several formats is harder to troubleshoot, because a card that does not work might be unenrolled, might be the wrong format, or might be a format the reader is not configured to pass through.

What Is OSDP and Should You Move to It?

OSDP is the open supervised device protocol, and it was designed specifically to fix what Wiegand cannot do.

It runs over a two wire serial connection rather than separate data lines. It is bidirectional, so the controller can query the reader and the reader can report its status. It supports supervision, so a missing reader raises an alarm rather than going quiet. And it supports encryption between reader and controller.

Wiegand against OSDP at a glance
 Wiegand 26 bitOSDP
DirectionReader to controller onlyBoth ways
Data linesTwo, plus power and groundTwo wire serial, plus power
SupervisionNoneSupported
EncryptionNoneSupported
Readers per cable runOneMultiple devices can share the bus
Existing panel supportNear universalDepends on the panel

The honest answer on migration is that it depends on the panel. Many readers support both, so the reader is rarely the obstacle. The controller and the head end software usually decide whether it is practical.

Does the Reader Technology Change the Wiegand Output?

Not the format, no. A keypad, a magnetic stripe reader and a smart card reader can all present a 26 bit Wiegand message to the same controller input.

Schlage KP keypad only reader module
A keypad only module. Keypad entries can be sent in several different ways, so how the keypad output is formatted is a separate setting from the card format.
Schlage MS magnetic stripe swipe reader module
A magnetic stripe module. The credential technology at the front is independent of the data format at the back, which is why these modules are interchangeable on the same panel input.

Where both a card and a code are needed, a combined module handles the two inputs and sends the result on the same interface.

Schlage MSK magnetic stripe with keypad reader module
A combined stripe and keypad module. Two factor at the door is a configuration decision, and it changes what the controller expects to receive for a single access attempt.

Our proximity card reader guide covers the reader side in detail, including mounting and multi technology options.

Why Do Wiegand Readers Stop Working?

Symptom and the usual cause
SymptomLikely causeCheck
Reader beeps, controller sees nothingData lines swapped, broken or no common groundContinuity on both data lines and the ground
Card reads but is never recognisedFacility code not enrolled, or the wrong formatEnrolled facility code against the card
Intermittent readsCable distance, noise, or a marginal supplyVoltage at the reader while it operates
Works on one door, not anotherDifferent format configured on that readerReader configuration, not the card
Reader dead, no indicatorSupply, or damage to the cable runSupply at the reader end of the cable
Works intermittently with door positionWiring crossing into a moving leafThe power transfer route, not the reader

That last row catches people regularly. If anything on the door side is wired through the moving leaf, the crossing fatigues long before the devices do. Our electric hinge guide covers it.

What Should You Confirm Before Ordering a Reader?

Six things. The format the controller expects, including the bit count. The credential technologies the site uses now and plans to use. Whether a keypad is required. The mounting position, which decides the physical size. The voltage available at the door. And whether the system is moving to a supervised protocol, because that may change the reader choice today.

Schlage MTK multi technology keypad reader module
A multi technology module with keypad. Where a site is partway through a credential migration, a reader that accepts more than one technology avoids changing the hardware twice.

For the wider system, our access control hardware integration guide covers how the reader, lock, door position switch and request to exit device work together, and the request to exit sensor guide covers the exit side.

About the Author

Security Parts has supplied repair parts for commercial door hardware since 2001, covering Von Duprin, LCN, Schlage, Falcon, Detex and Adams Rite at the component level. Our diagram based lookup exists so a technician can confirm a part before ordering it. This guide was written by the Security Parts team from supplier documentation and the questions our customers bring us.

If you know the panel but not which reader module suits it, contact us with the format the controller expects, or browse Schlage replacement parts and the electric strike parts section.

Request to Exit Motion Sensor: How REX Sensors Work and Fail

Quick Summary

Key points

  • A request to exit sensor tells the access control panel that somebody is leaving legitimately, so the door opening is logged as an exit rather than reported as a forced entry.
  • Two families do the job. A switch inside the lock or exit device signals when the hardware is operated. A motion sensor above the door signals when somebody approaches.
  • Passive infrared sensors look for the heat of a moving body. Microwave sensors look for movement itself. They fail for different reasons, which is why both exist.
  • Whether a sensor may release an electrically locked door, rather than only signal the panel, is a code question with specific conditions attached and it is decided locally.
  • Most false alarms on these doors are not the sensor failing. They are airflow, sunlight, traffic in the corridor or coverage aimed at the wrong area.
The two ways a door says somebody is leaving
MethodWhat triggers itWhere it sits
Request to exit switchThe lock, lever or exit device being operatedInside the hardware on the door
Request to exit motion sensorSomebody approaching the door from insideAbove the door on the secure side

A door with access control on it has an awkward problem. The reader knows who came in, but nothing tells the system who is going out, so every normal departure looks identical to somebody forcing the door.

Request to exit hardware solves that. This guide explains what the sensor is actually doing, how the motion sensing versions differ from the switch versions, where they go, and why so many of them end up being blamed for faults that are not theirs.

What Is a Request to Exit Motion Sensor and Why Is It Fitted?

It is a detector mounted above the door on the inside, aimed at the floor area somebody crosses on their way out. When it sees movement it closes a contact, and that contact tells the access control panel to expect the door to open.

The signal usually does two things. It suppresses the alarm that would otherwise be raised by the door position switch, and it creates a proper exit record in the log.

Detex MN01 PIR request to exit motion sensor
A passive infrared request to exit sensor. It mounts above the door on the secure side and looks down at the approach, so nobody has to press anything on the way out.

The reason it exists rather than just wiring a button is friction. A sensor asks nothing of the user, which matters on doors people go through with full hands, and on accessible routes where pressing a button may not be realistic.

What Happens If a Door Has No Request to Exit Signal?

Every legitimate exit is reported as a door forced open, and within a week nobody is reading the alarms any more.

That is the real cost of a missing request to exit signal. It is not that the door fails to work, it is that the monitoring becomes noise and a genuine forced door stops standing out from the thirty false ones that day.

The second effect is on records. Without an exit signal the system has entries but no departures, so occupancy reporting and roll call information are unreliable. Our door position switch and request to exit guide covers how the two signals work together.

Motion Sensor or Switch: Which Type of REX Do You Need?

They answer different questions, and on some doors you want both.

A switch inside the hardware signals that the device has actually been operated. It is precise. Nothing reports an exit unless somebody physically works the lever or pushed the bar.

Schlage RX-LC request to exit switch low current kit
A request to exit switch kit that fits inside the hardware. Because it reports mechanical operation rather than presence, it cannot be triggered by somebody simply walking past.

A motion sensor signals that somebody is approaching. It is earlier, which matters when the panel has to release a lock before the user reaches the door, and it is less precise, because approaching is not the same as leaving.

Choosing between a switch and a motion sensor
ConsiderationSwitch in the hardwareMotion sensor above the door
Triggers onHardware being operatedMovement in the detection area
TimingAt the moment of exitBefore the user reaches the door
False trigger riskVery lowHigher, depends on the environment
Needs the user to touch anythingYes, the lever or barNo
Suits releasing a lock in advanceNoYes

On exit devices, the switch version is often built into the bar itself rather than added separately.

Schlage 692 SmartBar request to exit switch
A request to exit function built into the push bar. Where the door already has an exit device, this is usually tidier than adding a separate sensor above the opening.

How Does a PIR Request to Exit Sensor Work?

Passive infrared sensors detect the heat a human body gives off, and specifically detect it moving across the detection pattern.

The word passive matters. The sensor emits nothing. It simply watches for a change in the infrared energy reaching it, which is why these units draw very little power and why they do not interfere with anything else.

Detex MN02 passive infrared request to exit sensor
A second passive infrared sensor option. Coverage pattern and adjustment range are what separate one PIR unit from another, so the specification matters more than the appearance.

What does a PIR sensor struggle with?

Moving air at a different temperature, which is why a sensor near a heater, an air conditioning outlet or a draughty vestibule misbehaves. Direct sunlight across the detection area causes the same problem. So does a person approaching very slowly, because the sensor is watching for change rather than presence.

When Is a Microwave Sensor the Better Choice?

When the environment defeats infrared, or when you need detection through something.

Microwave sensors transmit a signal and watch for the shift that comes back from a moving object. They are not affected by air temperature, they are less troubled by sunlight, and they detect motion rather than heat.

Detex 104758-1 microwave motion sensor
A microwave motion sensor. It suits openings where airflow or sunlight makes infrared unreliable, at the cost of being harder to keep inside a tight detection area.

The trade is containment. Microwave energy does not respect the boundaries you would like it to, so a badly set unit detects movement on the other side of a partition or in the corridor beyond. Setting the sensitivity properly is more of a job than it is with infrared.

Where Should a Request to Exit Sensor Be Mounted?

Above the door, on the secure side, aimed down at the area a person crosses immediately before reaching the door.

Three mistakes account for most poor installations. Mounting the sensor so the pattern reaches past the door into a corridor, which means passers by trigger it. Mounting it so the pattern does not reach far enough, so the lock does not release until the user is already pulling the handle. And mounting it where the door itself swings through the detection area, so the door triggers the sensor on its way closed.

How do you check the coverage is right?

Walk it. Approach the door at normal walking pace from the direction people actually use and note where the sensor picks you up. Then walk past the door without stopping and confirm it does not. Both tests matter, and most units are set using only the first.

Can a Motion Sensor Release a Magnetic Lock on Its Own?

This is the question that matters most and the one with the most careful answer.

Codes treat electrically locked egress doors as a special case, and sensor release of those doors carries specific conditions, which typically include a manual release device and a requirement that the lock fails unlocked on loss of power. Exactly what is permitted, and on which doors, is decided by the authority having jurisdiction.

So the honest answer is that a sensor can be part of a compliant arrangement, and is not by itself a substitute for a mechanical means of escape. Treat the sensor as one element of a designed egress solution, not as the solution.

Our electromagnetic lock parts guide covers the egress rules that apply to maglocks, and the delayed egress guide covers the case where the door is deliberately held.

How Is a Request to Exit Sensor Wired In?

Two connections matter: power to the sensor, and the contact back to the panel.

Power is usually taken from the same supply feeding the lock and the reader at that door. The contact is a dry relay output, and the panel expects it in a particular state, either normally open or normally closed. Getting that backwards produces a door that is permanently in request to exit, which suppresses the alarm the whole time and quietly removes the monitoring you installed the sensor to provide.

What to establish about the panel before wiring
QuestionWhy it matters
Normally open or normally closed inputWrong state leaves the door permanently unmonitored
Voltage available at the doorSensors are specified for a range, not any supply
Does the panel or the sensor hold the timingTwo timers fighting each other causes erratic behaviour
Is the sensor also releasing a lockChanges both the wiring and the code position

Why do these doors fail intermittently?

More often than not it is not the sensor at all. If anything electrified sits in the moving leaf, the wiring has to cross from the frame to the door, and that crossing is the part that fatigues. A fault that changes with door position is almost always the transfer route rather than the device. Our electric hinge guide covers why.

The other common cause is a supply that measures correctly at rest and sags when the lock operates. Measure voltage at the device while the door is actually working, not with everything idle.

Why Do Request to Exit Sensors False Trigger?

False trigger causes and what to change
CauseHow it shows upWhat to do
Airflow across the patternRandom triggers, worse when heating or cooling runsReaim away from vents, or move to microwave
Direct sunlightTriggers at the same time each dayReaim, shade the area, or change technology
Pattern reaching into the corridorTriggers when nobody approaches the doorReduce coverage or sensitivity
Door swinging through the patternA second trigger just after every exitReaim so the leaf stays out of the area
Microwave through a partitionTriggers from an adjacent roomReduce sensitivity, confirm by walking the far side
Vibration on the mountingIntermittent, worse on a loose frameSecure the mounting before changing the unit

The pattern across all of these is that the sensor is usually reporting exactly what it sees. Before replacing one, prove what is moving in the detection area.

What Do You Need to Confirm Before Ordering?

Six things settle the order. The technology, infrared or microwave, based on the environment. The output type the panel expects, and whether it needs a normally open or normally closed contact. The voltage available at the door. Whether a timer or adjustable hold is required. The mounting position and the coverage the opening actually needs. And whether the door is part of an electrically locked egress arrangement, because that changes what is permitted.

If you are specifying the whole opening rather than replacing one sensor, our access control hardware integration guide covers how the reader, the lock, the door position switch and the request to exit device fit together, and the electric strike parts section covers the locking side.

About the Author

Security Parts has supplied repair parts for commercial door hardware since 2001, covering Von Duprin, LCN, Schlage, Falcon, Detex and Adams Rite at the component level. Our diagram based lookup exists so a technician can confirm a part before ordering it. This guide was written by the Security Parts team from supplier documentation and the questions our customers bring us.

If a door is raising forced alarms on every exit and you are not sure what is fitted above it, contact us with a photograph of the head of the opening, or browse Detex parts for the sensor range.

Proximity Card Readers Explained: Credentials, Mounting and Wiring

Quick Summary

Key points

  • A proximity card reader reads a credential held near it and sends the result to a controller. It does not decide anything itself and it does not lock or unlock the door.
  • Readers are chosen by mounting as much as by technology. Mullion mount, wall mount and mini mullion are different bodies doing the same job in different spaces.
  • Multi technology readers accept more than one card format, which is what makes a credential migration possible without changing every reader on day one.
  • Which card technologies a reader accepts can be changed in the field with configuration cards rather than by swapping hardware.
  • A reader with a keypad turns one factor into two, because the user has to present something and know something.
What the reader does and does not do
FunctionReaderController
Reads the credentialYesNo
Decides whether to grant accessNoYes
Releases the lockNoYes, through the lock hardware
Holds the list of who is allowed inNoYes

The reader is the part of an access control system everybody sees and the part that does the least thinking. Understanding that split explains most of what is confusing about specifying one.

This guide covers what a proximity reader actually does, how mounting and technology are separate decisions, and what to confirm before ordering. For how the reader fits into the rest of the opening, see our access control and door hardware integration guide.

How Does a Proximity Card Reader Work?

A proximity reader emits a field. When a card or fob enters that field, the credential draws enough energy from it to power itself and transmit its number back. The reader picks up that number and passes it on.

Two things follow from that and both matter in practice.

First, the credential has no battery. It is powered entirely by the reader's field, which is why a card works for years and why it stops working at a distance. Range is a property of the field, not of the card.

Second, the reader is not making a decision. It reads a number and sends it to the controller. The controller holds the list of who is permitted, checks the number against it, and decides whether to release the door. If the door does not open, the reader is usually not the thing that refused.

Schlage PR10 mini mullion proximity card reader for narrow stile and mullion mounting
A mini mullion reader is built narrow so it fits on the mullion of a storefront pair or a narrow stile frame.

Mullion, Wall or Mini: Why Mounting Decides the Part

Readers performing the same function come in different bodies, and the body is chosen by where it has to live.

Reader bodies by mounting position
MountingShapeWhere it goes
Mini mullionNarrowest bodyNarrow stile frames and mullions with very little width
Mullion mountTall and narrowThe vertical mullion between a pair of glazed doors
Wall mountWider, often single gangA wall beside the door, where there is room
Wall mount with keypadLarger again, keys plus read areaWhere a PIN is required as well as a card
Reader moduleComponent rather than finished unitBuilt into another assembly

Mullion readers exist because storefront doors leave almost nowhere to put anything. The mullion between the leaves is often the only vertical surface near the handle, and it is narrow, so the reader is built to match.

This is also why ordering goes wrong. The technology is identical across several of these, so somebody orders the wrong body and it physically will not fit the only place it can go.

Schlage MT15-485 wall mount multi technology card reader for access control
Wall mount readers are wider than mullion units and suit a jamb or wall beside the door rather than a storefront mullion.

What Is a Multi Technology Reader and Why Does It Matter?

Card technologies are not one thing. Older proximity formats, smart card formats and various proprietary schemes all exist in the same buildings, usually because the estate was built over decades.

A multi technology reader accepts more than one of those formats at the same reader. That turns an impossible migration into a manageable one.

Without it, changing credential technology means changing every reader and every card on the same weekend, because a reader that only understands the old format cannot read a new card and vice versa. With multi technology readers, you change the readers first, keep issuing old cards while both work, then switch credentials at your own pace and turn the old format off at the end.

That is why multi technology units dominate current ranges, and why the stocked line includes plain multi technology readers, keypad versions, mullion and wall bodies, and government specification variants built to federal credential requirements.

Reader Modules Versus Finished Readers

Some products in the range are described as reader modules rather than readers. A module is the reading electronics intended to be built into another assembly, rather than a finished unit with its own housing. If you are replacing something on a wall, you want the finished reader. If you are servicing an integrated product, you may want the module.

Schlage MTB11 mullion mount multi technology proximity card reader
Mullion mount readers are tall and narrow so they fit the vertical mullion of a glazed pair.

How Do You Change Which Card Technologies a Reader Accepts?

This is the part most people do not know exists, and it saves a surprising amount of trouble.

On multi technology readers, the set of card formats the reader will accept is configurable. Rather than returning the unit or editing anything in software, the change is made by presenting a configuration card to the reader.

The stocked range includes cards that enable all proximity card technologies, cards that disable all of them, and cards that turn individual technologies on or off one at a time. There are also configuration cards covering card serial number bit lengths.

Why that matters: a reader that accepts every format it can is convenient and is also reading credentials you may not want accepted. Turning off the technologies a site does not use narrows what will open the door. It also stops a reader responding to a visitor's card from an unrelated system, which is the sort of thing that generates confusing access logs rather than a real breach.

Keep the configuration cards with the site records. They are small, they look like ordinary cards, and a reader that has been reconfigured by somebody who then left is a puzzle nobody enjoys.

When Should a Reader Have a Keypad?

A card on its own is something you have. Anyone holding the card is treated as the person it belongs to, which is fine for most doors and inadequate for some.

Adding a keypad adds something you know. The user presents a credential and enters a PIN, so a lost or borrowed card is not enough on its own. Most ranges offer a keypad version of the same reader body, so the decision does not change the mounting.

Where that is usually worth it:

  • Server rooms, comms rooms and plant spaces.
  • Cash handling and stock rooms.
  • Doors that are rarely used, where a missing card may not be noticed for weeks.
  • Out of hours access on a door that is open to card only during the day.

Where it usually is not: high traffic main entrances, where a PIN at every entry creates a queue and encourages people to hold the door for each other, which defeats the whole arrangement.

What Does a Reader Need to Be Wired To?

A reader needs power and a data path back to the controller, and in most installations those run in the same multi conductor cable.

Three practical points come up on nearly every job.

  • Metal affects range. Mounting a reader directly on a metal mullion or frame changes its field. Readers intended for mullion mounting are designed with that in mind, which is another reason to use the right body rather than the one that fits.
  • Cable runs have limits. Readers are rated for a maximum distance to the controller, and exceeding it causes intermittent reads that look like a faulty reader.
  • Keep reader cable away from lock power. The lock circuit switches a relatively large current, and running it alongside the reader data pair is a reliable way to create faults that come and go.

The lock itself is a separate decision from the reader. For what releases the door once the controller says yes, see our comparison of an electrified mortise lock versus an electric strike and our electromagnetic lock parts guide.

Why Reader Covers Are Ordered Separately

On several readers the outer cover is a separate part number with its own colour, and this catches people out on a replacement.

The stocked covers come in a range that includes black, cream, warm tone brown and cool tone gray, and they are specific to the reader body and gang size. A single gang cover is not a double gang cover, and a cover for one reader family will not clip onto another.

Two situations where this matters. The first is damage: a cracked cover does not mean a new reader, it means a cover. The second is appearance: a reader replaced like for like in function can look wrong on the wall if the cover colour was chosen to match a previous decor scheme.

When ordering a reader for an existing location, confirm whether the cover is included or separate, and record the colour from the one already on the wall.

What Goes Wrong With Card Readers?

Reader symptoms and where to look
SymptomLikely causeCheck first
Reader shows no light at allPower not reaching the unitSupply at the reader terminals, then the cable run and the controller end
Reader beeps but the door never releasesReader is working, the decision or the lock is notWhether the controller logged the read, then the lock circuit
Some cards work, others do notCard technology not enabled on that readerWhich formats the reader is configured to accept
Read range has droppedMounting surface or interferenceWhether anything metal has been installed near the reader recently
Intermittent reads with no patternCable length or routingDistance to the controller, and whether lock power shares the route
Reader works, door opens, no recordMonitoring devices missing or faultyThe door position switch and the request to exit device

The second row is the one worth internalising. A reader that beeps and flashes has done its job. If the door did not open, the problem is downstream of the reader, and replacing the reader will change nothing.

The Reader Is Only Half of a Monitored Door

A reader tells the system somebody presented a valid credential. It does not tell the system whether the door actually opened, whether it closed again, or whether somebody left through it.

That is the job of two other devices. A door position switch reports whether the leaf is open or closed. A request to exit device reports that somebody on the inside operated the hardware to leave. Without those, an access control system knows who was granted access and nothing about what happened next.

Our guide to request to exit and door position switches covers both and how they are wired.

What to Confirm Before Ordering a Reader

  1. The mounting position, which decides the body: mini mullion, mullion, wall or keypad.
  2. The card technologies in use on site, and any migration planned.
  3. Whether a keypad is needed for that specific door.
  4. Any government or federal credential requirement, which is a distinct product variant.
  5. The interface and cable run back to the controller.
  6. The finish and cover, which on several readers is a separately ordered part.

Browse Schlage parts for readers, modules, covers and configuration cards, or the full products and parts index if you already have a part number.

About the Author

Security Parts has supplied repair parts for commercial door hardware since 2001, covering Von Duprin, LCN, Schlage, Falcon, Detex and Adams Rite at the component level. Our diagram based lookup exists so a technician can confirm a part before ordering it. This guide was written by the Security Parts team from supplier documentation and the questions our customers bring us.

For the rest of the electrified opening, see our electric strike schematic diagram and the electric strike parts section.

Request to Exit and Door Position Switches: What They Do and How to Wire Them

Quick Summary

Key points

  • A door position switch reports one thing only: whether the door leaf is open or closed. It knows nothing about the latch, the lock or the credential.
  • A request to exit switch reports that somebody on the inside pushed the bar or the lever, so the panel can tell a legitimate exit from a break-in.
  • The two are wired to different inputs on the panel and they do different jobs. Fitting one does not cover the other.
  • Most of these switches are SPDT, which gives you a normally open and a normally closed contact from the same device. Which pair you land on decides whether a cut wire raises an alarm or hides one.
  • On exit devices the monitoring is ordered as suffix codes. RX, LX and SS each watch a different thing, and picking the wrong one is the most common ordering mistake on a monitored opening.
The two switches at a glance
SwitchSensesPanel uses it to
Door position switch (DPS)Door leaf open or closedRaise forced open and held open alarms, relock on close
Request to exit switch (RX)Push bar, touch pad or lever being operatedSuppress the forced open alarm while somebody leaves
Latch monitor (LX)Latch bolt projected or retractedProve the opening is actually secured, not just shut

Two switches turn an ordinary opening into a monitored one, and they are constantly mixed up. A technician is told the door needs monitoring, fits one switch, and the panel still throws a forced door alarm every time somebody leaves. The hardware is fine. The wrong switch was fitted, or the right switch was wired to the wrong contact.

This guide covers both devices at component level: what each one senses, how the contacts behave, which part fits which door, and what the wiring actually has to do at the panel. For how these switches sit inside a wider electrified opening, see our access control and door hardware integration guide.

What Is a Door Position Switch and What Does It Actually Monitor?

A door position switch, usually shortened to DPS, monitors whether the door is open or closed, independent of the latch state. That last part is the bit people miss. The switch watches the gap between the leaf and the frame. It does not know whether the latch bolt has thrown, whether the lock is secure, or who opened the door.

Physically it is two pieces. A switch body goes in the frame and a magnet or actuator goes in the door edge opposite it, so closing the door brings them together and changes the state of the contacts. Pull the door open and the contacts change back.

That single piece of information drives most of what an access control system does after the door opens:

  • Door forced open. The door went open with no valid credential and no exit request. Without a DPS the panel cannot detect this at all.
  • Door held open. The door has been open longer than the allowed time, so something is propping it.
  • Relock on close. Fail secure hardware can be told to drop back to locked the moment the door closes, rather than waiting out a fixed timer.
  • Interlocks and operators. Automatic operators and mantraps need to know the leaf is closed before the next thing is allowed to happen.

Why the Latch State Is a Separate Question

A closed door is not a locked door. A door can sit closed against the stop with the latch bolt held back, and a DPS will happily report closed. If you need to know that the opening is actually secured, you need latch monitoring as well, which on an exit device is a different switch entirely.

What Is a Request to Exit Switch and Why Is It Required?

A request to exit switch, written RX or REX, generates a signal to the access control panel whenever the push bar or touch pad is actuated. It is how the panel tells a person leaving the building from a person forcing the door.

Without it the system has no way to interpret an opening from the inside. Somebody pushes the bar, the door swings, the DPS reports open, and because no credential was presented the panel calls it a forced door. Every legitimate exit becomes an alarm, and within a week nobody is reading the alarms any more.

On access controlled egress doors the request to exit signal is not optional. The egress side has to stay mechanically free, so the building relies on the RX signal to keep the monitoring honest rather than restricting the exit itself.

How the Shunt Window Works

When the RX contact changes state, the panel records an egress event and suppresses the door forced alarm for a set period, typically in the range of five to ten seconds. That window is called the shunt. The door is expected to open and close again inside it.

Two things go wrong with shunt timing. Set it too short and a slow closer or a person holding the door produces nuisance alarms. Set it too long and somebody can push the bar, prop the door and walk away with the alarm suppressed. The shunt is a security setting, not just a convenience setting.

Door Position Switch vs Request to Exit: What Is the Difference?

Put plainly: the DPS watches the door, the RX watches the hardware being operated. A monitored opening normally needs both, wired to two separate panel inputs.

Door position switch compared with request to exit
QuestionDoor position switchRequest to exit switch
What it sensesDoor leaf open or closedPush bar, touch pad or lever being operated
Where it mountsDoor edge and frame, or door face and frame faceInside the exit device or lock body
What the panel does with itRaises forced open and held open alarms, triggers relockSuppresses the forced open alarm for the shunt window
Does it know the latch is thrownNoNo, unless you also fit latch monitoring
Does it know who opened the doorNoNo
What happens if you omit itNo forced entry detection at allEvery normal exit reads as a forced door

What Do the Exit Device Switch Codes RX, LX, SS and LC Mean?

On exit devices the monitoring is not a separate box on the wall. It is a switch kit inside the device, ordered as a suffix on the part number. Four codes come up constantly and they are not interchangeable.

Exit device monitoring suffixes and what each one watches
CodeFull nameWhat it monitorsTypical use
RXRequest to exitSignals the panel when the device is actuatedAny access controlled egress door
LXLatch monitorWhether the latch bolt is projected or retractedProving the opening is actually secured
SSSignal switchBar depression, as a dry contact that closes when the push bar or touch pad is depressedSimple egress signalling where latch state is not needed
LCLow currentNot a sensing function. It is the low current switch configurationMatching the switch rating to low current panel inputs

Why LX and RX Are Not the Same Thing

This is the ordering mistake that costs the most. LX reports the latch bolt. RX reports the egress event. A door can give you a clean LX signal and still produce forced door alarms all day, because the panel was never told that somebody pushed the bar.

SS sits between them. It is simpler than RX because it monitors the bar being depressed rather than the latch retracting, which is enough for a basic egress signal but tells you nothing about whether the device actually released.

Kits are also length specific. A switch kit built for a 48 inch device will not serve a 36 inch device, so the device width has to be confirmed before the kit is ordered. Browse the exit device parts section for the switch kits that match your device.

Von Duprin 050291 LX-RX-LC switch kit for a 4 foot exit device, combining latch monitoring and request to exit
A combined kit carries more than one function. This one provides latch bolt monitoring and request to exit monitoring in a single assembly sized for a 48 inch device.

Which Door Position Switch Fits Which Door?

Door position switches are not generic. The two things that decide the part number are how it mounts and what the door and frame are made of. A switch bored into a hollow metal frame is a different part from the one that surface mounts on an aluminium storefront.

Door position switch selection by mounting and door material
PartMountingDoor and frameSwitch typeRating
Schlage 679-05ConcealedUsed in electronic access control applicationsSPDT0.3 A at 30 VDC
Schlage 679-05HMConcealedHollow metal doors and framesSPDT0.3 A at 30 VDC
Schlage 679-05WDConcealedWood doors and framesCheck the current data sheetCheck the current data sheet
Schlage 7766Surface mount, magneticAluminium, wood and hollow metalSPDT0.25 A at 30 VDC
LCN 8310-805Surface mountUsed with automatic operatorsCheck the current data sheetCheck the current data sheet

Concealed switches disappear into the opening and cannot be tampered with from the occupied side, but they need a prep in both the door edge and the frame. That prep is straightforward on a new opening and a real job on an existing one. Surface mount magnetic switches need no prep at all, which is why they dominate retrofits, but they are visible and they sit where a trolley or a cart can hit them.

Schlage 679-05 concealed door position switch for electronic access control
A concealed door position switch mounts out of sight in the frame, with its actuator opposite in the door edge.

What Do SPDT, Form A, Form B and Form C Mean?

Nearly every spec sheet for these switches uses contact form language, and getting it wrong is how a monitored door ends up quietly unmonitored.

Contact forms in plain language
TermWhat it meansBehaviour
Form ASingle pole single throw, normally openOne pair of contacts. Open at rest, closed when actuated
Form BSingle pole single throw, normally closedOne pair of contacts. Closed at rest, open when actuated
Form CSingle pole double throw, also written SPDTA common terminal plus both a normally open and a normally closed contact. You choose which pair you use
Dry contactA contact that supplies no voltage of its ownIt simply makes or breaks a circuit the panel powers

Most of the door position switches on this site are SPDT, which is the same thing as Form C. The Schlage 679-05 provides normally open and normally closed contacts from the one device, and the Schlage 7766 is also SPDT. That gives you a choice at install time, and the choice matters more than it looks.

Normally Closed Is Usually the Safer Default

Wire a DPS on the normally closed contact and the circuit sits closed while the door is shut. Open the door and the circuit breaks, so the panel sees a change. Cut the wire, pull the switch off the frame, or lose a connection in the loop and the panel also sees a break. The failure looks like an alarm.

Wire the same switch normally open and a cut wire looks exactly like a door that is sitting quietly closed. Nothing is reported. On a door that matters, supervise the loop or use the normally closed contact so that a fault announces itself.

How Do You Wire a Door Position Switch?

The electrical side is simple. The complications are mechanical and they are all about the gap.

The switch is a dry contact into a monitor input on the panel or controller. Two conductors run from the switch to that input, and the panel supplies whatever small voltage it needs to sense the state.

The ratings are modest for the same reason. The Schlage 679-05 and 679-05HM are rated 0.3 amps at 30 VDC, and the 7766 is rated 0.25 amps at 30 VDC. These are signalling contacts, not switching contacts. Never run lock current through them.

What actually causes trouble on site:

  • Alignment. Magnetic switches have a working gap. Push past it and the contacts stop changing reliably, so a door that looks shut reports open. A sagging door, a worn hinge or a closer that is not pulling the leaf fully home all show up here first.
  • Which leaf it goes on. On a pair, the switch belongs on the active leaf unless both leaves need monitoring, in which case you need two switches and the panel has to treat them sensibly.
  • Getting the wires across. If the switch sits in the door rather than the frame, the conductors have to cross the hinge line, which means a power transfer or an electrified hinge. Our electric power transfer guide covers how to do that without creasing a conductor.
  • Keeping signal away from power. Run the monitoring pair separately from lock power. Shared conduit with a switching load is a reliable way to manufacture phantom door events.

How Do You Wire a Request to Exit Switch?

An RX switch is also a dry contact, but it can be used in two completely different ways, and conflating them is the root of most REX confusion.

Shunting Versus Unlocking

Shunting is the normal case. The RX contact goes to the panel's request to exit input. Somebody pushes the bar, the panel opens the shunt window, the DPS reports the door opening, and no alarm is raised. The lock itself does nothing, because an exit device already releases mechanically.

Unlocking applies where the egress side is not mechanically free, for example a fail secure electric strike on a door with a lever that is locked from the inside. Here the request to exit device, often a sensor or a button rather than a bar switch, has to actually release the lock. That is a different circuit with life safety consequences, and it is the case where a failed switch traps people rather than just producing a nuisance alarm.

Know which of the two you are building before you pick the part. For the broader comparison of what releases a door and when, see our guide to an electrified mortise lock versus an electric strike and our electromagnetic lock parts guide, since a maglock opening handles egress differently again.

Switch Kits Are Device Specific

A request to exit switch for an exit device is ordered against the device family and the device width. A Von Duprin 050251-CON request to exit switch with connector installed, for example, is listed as fitting 22, 33A, 35A, 98 and 99 style devices. Confirm both the series and the rail length before ordering, and check the Von Duprin 98/99 series parts manual if you are working on those devices.

What Do Electronic Locks Use Instead of a Separate Switch?

Standalone and networked electronic locks often carry their own monitoring rather than relying on a switch in the frame. The request to exit function is built into the lever, because turning the inside lever is itself the egress event, and the lock reports it over its own connection.

Door position is the part that still needs hardware. On Schlage NDE series locks the door position function is supplied as a DPS wiring kit containing a magnet, a switch and a wiring harness. The same part is listed for LE series mortise deadbolt locks as an external DPS kit. If the lock was ordered without it, the function is simply absent until the kit is fitted.

Schlage L483-055 door position switch DPS wiring kit with magnet, switch and harness for NDE and LE series locks
Electronic locks take door position as a kit rather than a frame mounted switch. This one covers NDE series and LE series mortise deadbolt locks.

Mortise locks can also carry signalling internally. A signal switch mortise lock reports hardware operation from inside the lock case, which keeps the monitoring hidden and removes a separate device from the frame. For the mechanical side of those lock bodies, see our Schlage L series mortise lock component guide.

How Does Door Position Monitoring Work on an Automatic Operator?

On an automatic door operator the switch is doing something different again. It is not feeding an alarm panel, it is feeding the operator's own safety logic.

The LCN 8310-805 is a surface mount door position switch that disables the approach side sensor when the door is closed. It is applied with the 8310-804-1 or 8310-804-2 door mounted safety sensor and the 8310-845 relay module, working with an electrohydraulic, pneumatic or Benchmark automatic operator. A concealed version, the 8310-805C, covers installations where a surface device is unacceptable.

The reason this exists is that a door mounted sensor sweeps a different area as the leaf swings. Leaving the approach side sensor active through the whole cycle produces false detections and a door that will not settle. The position switch tells the operator which part of the cycle it is in.

Should You Use a Magnetic or a Mechanical Door Position Switch?

Both are in service everywhere and the choice is usually decided by the opening rather than by preference.

Magnetic switches use a reed contact in the switch body and a magnet in the door. Nothing touches, so there is nothing to wear out and nothing to bind when the door is slightly out of alignment, within the working gap. They are the practical choice for high cycle doors and for retrofits, since the surface mount versions need no door prep.

Mechanical plunger switches use a physical actuator that the door depresses as it closes. They are not fooled by an external magnet, which matters where tampering is a real concern, but the plunger is a moving part in the path of the door and it wears.

Where tamper resistance is the whole point, high security balanced magnetic switches exist as a separate class, built so that holding an external magnet against the frame does not defeat them.

Schlage 7766 surface mount magnetic door position switch for aluminium, wood and hollow metal doors
Surface mount magnetic switches need no door prep, which is why they dominate retrofit work on existing openings.

What Goes Wrong With These Switches and How Do You Find It?

Almost every fault on a monitored opening reduces to one of six things. Work down this list before replacing anything.

Monitored opening troubleshooting
SymptomLikely causeWhat to check first
Forced door alarm on every normal exitNo request to exit signal reaching the panelWhether an RX switch is fitted at all, then whether its contact lands on the correct panel input
Door reports open when it is visibly closedGap exceeded, or the leaf is not pulling fully homeHinge wear, door sag, closer final force, and the alignment of switch to magnet
Door reports closed when it is openContact welded, magnet relocated, or a short in the loopMeter the contact across the door swinging, not just at rest
Intermittent events with no patternMonitoring pair sharing a route with switching lock powerWhether the signal pair is separated from the lock supply
Nothing reported at all, no alarms everWired to the normally open contact with an open circuit faultContinuity end to end, then move to the normally closed contact
Works with the door open, fails as it closesConductor pinched or creased at the hinge lineWalk the door slowly through the full swing while watching the transfer point

For faults that are mechanical rather than electrical, our commercial door hardware troubleshooting guide covers the closer, latch and strike side of the same opening.

What Should You Confirm Before Ordering?

Six details decide whether the part that arrives is the part that fits.

  1. Which function you actually need. Door position, request to exit, latch monitoring, or more than one of them.
  2. Mounting. Concealed, which needs a prep, or surface mount, which does not.
  3. Door and frame material. Hollow metal, wood and aluminium take different parts.
  4. Contact form and rating. Confirm the switch gives you the contact you intend to wire, and that the panel input sits inside the switch rating.
  5. Device series and length, for anything that goes inside an exit device.
  6. Whether the conductors cross the hinge line, which decides if you also need a power transfer.

Everything in this guide is stocked at component level. Start from the full products and parts index if you already know the part number, or work from the diagram for your device.

About the Author

Security Parts has supplied repair parts for commercial door hardware since 2001, covering Von Duprin, LCN, Schlage, Falcon, Detex and Adams Rite at the component level. Our diagram based lookup exists so a technician can confirm a part before ordering it. This guide was written by the Security Parts team from supplier documentation and the questions our customers bring us.

For the rest of the electrified opening, see our electric strike schematic diagram, the Von Duprin QEL conversion kit guide, and our explanation of what delayed egress is and when code requires it.