Concealed Vertical Rod Exit Devices: How CVR Works and What Fails

Quick Summary

Key points

  • A concealed vertical rod exit device latches at the head and the sill of the opening, with the rods running inside the door rather than across its face.
  • The appeal is a clean door and protected rods. The cost is service access, because reaching the rods usually means taking the device apart rather than unscrewing a cover.
  • Nearly every CVR complaint is a latching complaint, and nearly every latching complaint comes back to rod adjustment or to a strike that has moved.
  • Less bottom rod, written LBR, removes the bottom rod and latch so the device only latches at the head. It is common on fire doors where floor dirt is a problem.
  • CVR preparation is normally done when the door is made. Converting an existing door to concealed rods is rarely practical, which is why surface rod conversion kits exist.
Where a CVR device sits among the four exit device configurations
ConfigurationWhere it latchesVisible on the door
RimOne latch into a strike on the frame or mullionDevice only
Surface vertical rodHead and sillDevice plus rods on the door face
Concealed vertical rodHead and sillDevice only, rods are inside the door
MortiseOne latch in a case in the door edgeDevice only

Concealed vertical rod devices look like the obvious choice right up until the first service call. They give you a clean pair of doors with nothing running up the face, and then eighteen months later the top latch stops engaging and nobody can work out how to get at the rod.

This guide explains what the device is actually doing, where it is the right answer, where it is not, and how to work through the latching problems that make up most of the service work on these openings.

Von Duprin 050575 bottom rod kit for a concealed vertical rod exit device
Rod length is set at installation and drifts as the door settles. Bottom rod kits are stocked separately, so an adjustment that has run out of thread is a parts order rather than a device replacement.

What Is a Concealed Vertical Rod Exit Device?

A concealed vertical rod exit device, usually shortened to CVR, is an exit device that latches the door at two points: a latch at the top that engages a strike in the frame head, and a latch at the bottom that engages a strike in the threshold or floor.

The two latches are driven by rods that run from the device up and down inside the door. Pushing the touchpad pulls both rods at once, retracting both latches, and the door is free.

Von Duprin 3347A/3547A-EO concealed vertical rod exit device, exit only
From the inside, a concealed vertical rod device looks like any other exit device. The difference is entirely inside the leaf, where the rods run to the top and bottom latches.

The word that does the work is concealed. On a surface vertical rod device, the same mechanism exists but the rods are visible on the face of the door, held in place by brackets. On a CVR device the rods live inside the door and nothing shows.

How Does a CVR Device Latch the Door?

Three parts have to agree for the door to latch: the latch itself, the rod that drives it, and the strike it engages. If any one of those three is out of position the door will not stay shut, and all three are adjustable.

The top latch engages a strike mounted in the frame head. The bottom latch engages a strike set into the threshold, or in some configurations drops into a floor socket.

Detex 95T top strike for concealed vertical rod exit devices
The top strike is as much a part of the latching system as the latch is. A strike that has shifted, or a frame that has settled, produces exactly the same symptom as a rod out of adjustment.

Why two latching points changes the behaviour

A rim device has one latch. If it engages, the door is shut. A CVR device has two, and the door can appear shut while only one of them is doing anything.

That is the source of most CVR confusion. Somebody pulls the door and it holds, so the device is assumed to be working, when in fact only the top latch is engaging and the bottom latch has been missing its strike for months.

CVR vs SVR vs Rim vs Mortise: Which Device Type Is on Your Door?

Identification takes about ten seconds once you know what to look at, and it has to be settled before any part is ordered because the latching components differ completely between configurations.

Identifying the configuration at the door
What you seeConfigurationWhere the parts live
No rods, a strike on the frame or on a mullionRimSingle latch in the device chassis
Rods visible on the door face, top and bottomSurface vertical rodExposed rods, latches top and bottom
No visible rods, latches at head and sillConcealed vertical rodRods inside the leaf
No rods, latch emerges from the door edgeMortiseMortise case in the door edge

Pairs of doors are the usual home for vertical rod devices, because without a mullion between the leaves there is nothing in the middle for a rim latch to engage. Our mullion guide covers the alternative approach to the same problem.

If you have established that the device is rim rather than vertical rod, our rim exit device guide is the better starting point.

Why Would You Specify Concealed Vertical Rod?

Three reasons come up repeatedly, and they are all good ones.

Appearance is the first. On a glazed entrance or a prestigious opening, rods running up and down the face of the leaf are the visual element nobody wants. Concealing them leaves a clean door.

Protection is the second. Exposed rods get knocked by trolleys, caught by luggage and bent by people pushing on them. Rods inside the door cannot be reached, so they cannot be damaged by ordinary traffic.

Security is the third. There is nothing on the surface to interfere with, which matters on doors that are accessible to the public outside staffed hours.

What Are the Drawbacks of CVR?

The drawbacks are all versions of the same thing: the parts you most need to reach are the ones you cannot see.

What concealment costs you
DrawbackWhat it means in practice
Service accessReaching a rod usually means removing the device and working inside the leaf
DiagnosisYou cannot watch the rods move, so faults are inferred rather than observed
Bottom latch environmentThe sill collects dirt, grit and water, and the bottom latch sits in it
Door preparationThe leaf has to be prepared for concealed rods, normally when it is made
RetrofitConverting an existing unprepared door to CVR is rarely practical

That last point is the one that catches specifiers. Surface rod conversion kits exist precisely because moving in the other direction, towards exposed rods, is something you can do on site.

What Does LBR Mean and When Is It Used?

LBR stands for less bottom rod. The device is supplied without the bottom rod and bottom latch, so it latches only at the head.

The reason is the environment at the sill. A bottom latch sits where mop water, grit and floor dirt accumulate, and on a busy opening it is the component that stops working first. Removing it removes the problem.

LBR is common on fire rated openings, where the device still has to latch positively, but the designers would rather put all of that responsibility on the top latch than risk a bottom latch that is fouled with dirt. Where a bottom rod is removed, the configuration has to be the one the manufacturer intends, not simply the original device with parts left off.

Identifying an LBR device

Look at the bottom of the door. If there is no latch emerging from the bottom edge and no strike in the threshold, the device is either LBR or the bottom components have been removed by someone. Those are very different situations, and the door schedule is the way to tell them apart.

What Fails on a Concealed Vertical Rod Device?

The failures are consistent across manufacturers because the mechanism is the same shape everywhere.

Symptoms and where to look first
SymptomMost likely causeCheck before ordering parts
Door will not stay shutRod out of adjustment, or a strike that has movedWatch both latches with the door slowly closing
Top latches, bottom does notBottom rod length, or debris in the sill strikeClear the strike, then check rod adjustment
Device feels stiff on the touchpadBinding rod, or a latch not returning fullyOperate with the door open and listen at both ends
Door latches only when slammedCloser is not delivering enough force at the latchLatch speed on the closer before touching the device
Rattling when closedLatch engaging, but with excess clearance at the strikeStrike position rather than the device
Rod disconnected inside the leafFixing worked loose over timeRequires opening up, but it is a fixing not a device failure
Von Duprin 109361 top vertical rod for a vertical rod exit device
Rods are ordered individually, top and bottom, and they are not interchangeable. Confirm which end you are replacing and the device series before ordering, because length is specific to both.

How Do You Adjust Vertical Rods?

Adjustment is about travel, not about tension. The rod has to retract the latch far enough to clear the strike when the touchpad is pressed, and it has to let the latch return fully when the touchpad is released.

Work with the door open first so you can see what the latches are doing without the frame in the way. Press the touchpad, confirm that both latches retract fully, then release and confirm both return fully. A latch that returns sluggishly will not engage a strike reliably.

Then close the door slowly and watch where each latch meets its strike. If a latch is arriving high, low or off to one side, the strike is the thing to move, not the rod.

Why the door closer gets blamed and sometimes deserves it

A CVR device needs a positive push at the very end of the swing to drive both latches home. If the closer has lost its latch speed, the door drifts into the frame and the latches do not engage.

That presents as a device fault and is not one. Before stripping the device, check the closer. Our guide to adjusting a commercial door closer covers the latch valve, which is the adjustment that matters here.

What Changes on a Fire Rated CVR Device?

Fire rated configurations behave differently in two ways that matter every day.

Dogging is not available. A fire exit device may not be held in the retracted position, because the door has to latch every time it closes. If a device on a fire door has a dogging keyhole, something is wrong with how the opening was specified.

Latching has to be positive. The door has to actively latch, not merely come to rest against the frame, which is why rod adjustment on a fire rated CVR device is a life safety matter rather than a convenience one.

Our commercial door fire rating guide and the NFPA 80 inspection guide cover what an inspection is looking for on these openings.

Which Parts Do You Order and What Do You Need to Know First?

Four pieces of information settle a CVR parts order, and three of them have to be read off the door rather than guessed.

What to establish before ordering CVR parts
InformationWhere you get itWhat it decides
Device seriesStamping on the chassis or under the coverEverything, parts do not cross series
Fire rated or notLabel on the door edgeDogging parts, latch configuration
Full rods or LBRPresence of a bottom latch and sill strikeWhich rods and latches exist
Door heightMeasure itRod length

For the model level breakdowns, our 9947 CVR parts guide and 9847 CVR parts guide list the components by assembly, and the exit device parts section covers the wider range.

If you are still deciding between device types rather than repairing one, our exit device and panic bar comparison and the Von Duprin series comparison cover the choice, and panic hardware on commercial doors covers where the code requires a device at all.

About the Author

Security Parts has supplied repair parts for commercial door hardware since 2001, covering Von Duprin, LCN, Schlage, Falcon, Detex and Adams Rite at the component level. Our diagram based lookup exists so a technician can confirm a part before ordering it. This guide was written by the Security Parts team from supplier documentation and the questions our customers bring us.

If the device stamping is hidden under the cover and you would rather not pull the door apart to find it, contact us with a photograph of the device and the door, and we will narrow it down before you order.

Frequently Asked Questions

What is a concealed vertical rod exit device?
It is an exit device that latches the door at two points, a latch at the top engaging a strike in the frame head and a latch at the bottom engaging a strike in the threshold. The rods that drive both latches run inside the door, so nothing is visible on the face.
What is the difference between concealed and surface vertical rod?
The mechanism is the same. On a surface vertical rod device the rods are visible on the face of the door and held by brackets. On a concealed vertical rod device the rods run inside the leaf and nothing shows.
Why are vertical rod devices used on pairs of doors?
Without a mullion between the two leaves there is nothing in the middle for a rim latch to engage. Latching at the head and the sill solves that, which is why pairs without a mullion normally carry vertical rod devices.
What does LBR mean on an exit device?
LBR stands for less bottom rod. The device is supplied without the bottom rod and bottom latch, so it latches only at the head. It is used where floor dirt, grit and mop water would otherwise foul the bottom latch.
Why does my CVR door not stay shut?
Usually the rod is out of adjustment or a strike has moved. Open the door, press the touchpad and confirm both latches retract fully and return fully, then close the door slowly and watch where each latch meets its strike.
Can a concealed vertical rod device be fitted to an existing door?
Rarely. The leaf has to be prepared for concealed rods, and that preparation is normally done when the door is made. Converting in the other direction, to surface mounted rods, is something that can be done on site.
Can a concealed vertical rod device be dogged?
Standard devices can be, fire rated devices cannot. A fire exit device may not be held in the retracted position, because the door has to latch every time it closes. A dogging keyhole on a fire door is a sign something was specified wrongly.
Why does my door only latch when it is slammed?
The door closer is probably not delivering enough force at the very end of the swing. A vertical rod device needs a positive push to drive both latches home, so check the latch speed adjustment on the closer before stripping the device.
Are top and bottom vertical rods interchangeable?
No. They are ordered individually and the length is specific to the end of the door and to the device series. Confirm which end you are replacing, the series of the device and the door height before ordering.
What should I know before ordering concealed vertical rod parts?
Four things: the device series from the stamping on the chassis, whether the opening is fire rated, whether the device is full rod or less bottom rod, and the height of the door. Parts do not cross between device series.

Concealed vertical rod exit devices explained: how CVR latches at head and sill, how it compares with SVR and rim, what LBR means and what fails first.

Concealed vertical rod exit devices explained: how CVR latches at head and sill, how it compares with SVR and rim, what LBR means and what fails first.

Concealed vertical rod exit devices explained: how CVR latches at head and sill, how it compares with SVR and rim, what LBR means and what fails first.